Vpacket Hotwire 5100 Guida Utente Pagina 1

Navigare online o scaricare Guida Utente per Networking Vpacket Hotwire 5100. vpacket Hotwire 5100 User`s guide [en] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - AREA CODE CHANGE

AREA CODE CHANGEPlease note that the area code forParadyne Corporation in Largo, Floridahas changed from 813 to 727.For any Paradyne telephone number

Pagina 2 - CUSTOMER PREMISES

1-15100-A2-GB22-00December 1996About HotWire1What is the HotWire 5100 DSL Access System?Your HotWire 5170 Remote Termination Unit (RTU) is a componen

Pagina 3 - Printed on recycled paper

About HotWire 1-25100-A2-GB22-00December 1996About the 5170 Remote Termination UnitThe HotWire 5170 RTU is a standalone unit designed for the home off

Pagina 4 - Important Safety Instructions

About HotWire 1-35100-A2-GB22-00December 1996Equipment and Software RequirementsVerify that you have the following hardware and software before instal

Pagina 5 - Declaration of Conformity

2-15100-A2-GB22-00December 1996Installation2Before You Begin1. Check your package contents.2. Review software and hardware requirements in Chapter 1.

Pagina 6 - Contents

Installation 2-25100-A2-GB22-00December 1996Installing the HotWire 5170 Remote TerminationUnitFor RTU installation, you need the following: Cables an

Pagina 7 - December 1996

Installation 2-35100-A2-GB22-00December 1996 Procedure1. Turn Off your PC. Place your RTU on a flat surface near the PC.2. Insert the DSL cable 6-pin

Pagina 8 - About This Guide

Installation 2-45100-A2-GB22-00December 19964. Insert the Ethernet cable 8-pin plug into the jack marked LAN on your RTU.Insert the other end of the c

Pagina 9 - Product-Related Documents

Installation 2-55100-A2-GB22-00December 19966. Turn on your PC.7. Turn on the power switch on your RTU (see rear panel illustration). Verify thatthe L

Pagina 10 - About HotWire

Installation 2-65100-A2-GB22-00December 1996Installing the HotWire 5170 RTU Diagnostics UtilityThe RS232 cable must be connected between the RTU and y

Pagina 11 - Features

3-15100-A2-GB22-00December 1996Using the HotWire DiagnosticsUtility3TroubleshootingTypically, you run your Diagnostics Utility to help troubleshoot y

Pagina 12 - User Interface

HOTWIRE 5100 DSL ACCESS SYSTEMCUSTOMER PREMISESUSER’S GUIDEFOR 5170 REMOTE TERMINATION UNITDocument No. 5100-A2-GB22-00December 1996

Pagina 13 - Installation

Using the HotWire Diagnostics Utility 3-25100-A2-GB22-00December 1996Symptom Possible SolutionPossible CauseExperiencingseveral errors whiletransferri

Pagina 14 - About the RTU Rear Panel

Using the HotWire Diagnostics Utility 3-35100-A2-GB22-00December 1996Accessing the Main MenuYou can use the Diagnostics Utility to check the health an

Pagina 15 -  Procedure

Using the HotWire Diagnostics Utility 3-45100-A2-GB22-00December 1996Setting the Communication PortUse the following procedure to specify the COM port

Pagina 16 - Ethernet

Using the HotWire Diagnostics Utility 3-55100-A2-GB22-00December 1996Setting/Changing MAC AddressCAUTION:Be sure you understand the purpose of the MAC

Pagina 17 - Power-Up Self-Test

Using the HotWire Diagnostics Utility 3-65100-A2-GB22-00December 1996Setting Line Rate in SoftwareYou can view and/or set the line rate to match your

Pagina 18

Using the HotWire Diagnostics Utility 3-75100-A2-GB22-00December 1996Checking RTU Status" ProcedureTo verify that the RTU is functioning properly

Pagina 19 - Troubleshooting

Using the HotWire Diagnostics Utility 3-85100-A2-GB22-00December 1996Resetting the RTUUse the Reset operation to reinitialize the RTU. You may want to

Pagina 20

Using the HotWire Diagnostics Utility 3-95100-A2-GB22-00December 1996Viewing Transmission Statistics and Network Status ProcedureTo view statistics a

Pagina 21 - Accessing the Main Menu

Using the HotWire Diagnostics Utility 3-105100-A2-GB22-00December 1996Running Loopback TestsLoopback tests can help you isolate areas of trouble if yo

Pagina 22 - " Procedure

Using the HotWire Diagnostics Utility 3-115100-A2-GB22-00December 1996For the options window operation, select the values to be used during the testan

Pagina 23 - Setting/Changing MAC Address

Printed on recycled paper A5100-A2-GB22-00December 1996Copyright  1996 Paradyne Corporation.All rights reserved.Printed in U.S.A.NoticeThis publicati

Pagina 24 - Setting Line Rate in Software

Using the HotWire Diagnostics Utility 3-125100-A2-GB22-00December 1996Downloading FirmwareUse the following procedure to download firmware updates fro

Pagina 25 - Checking RTU Status

A-15100-A2-GB22-00December 1996LEDsAThe HotWire RTU has eleven functional LEDs. The following illustration showsthe location of the LEDs on the facep

Pagina 26 - Resetting the RTU

LEDs A-25100-A2-GB22-00December 1996Table A-1. Front Panel LED Descriptions and Status (2 of 2)Type Indicating . . .LED is . . .LEDDSLTX Blinking, OnO

Pagina 27

B-15100-A2-GB22-00December 1996Pin AssignmentsBDSL InterfaceTable B-1 defines the pinouts for the DSL connector. It is a 6-pin, non-keyed,modular-jac

Pagina 28 - Running Loopback Tests

Pin Assignments B-25100-A2-GB22-00December 1996Ethernet InterfaceTable B-2 defines the pinouts for the Ethernet connector. It is an 8-pin,non-keyed, m

Pagina 29 - Loopback Test Results

Pin Assignments B-35100-A2-GB22-00December 1996RS-232 InterfaceTable B-3 defines the pinouts for the RS-232 connector. This serial connector is aDual

Pagina 30 - Exiting the Utility

C-15100-A2-GB22-00December 1996Technical SpecificationsCTable C-1 lists the technical specifications for the Customer Premises RemoteTermination Unit

Pagina 31 - 496-15214

GL-15100-A2-GB22-00December 1996GlossaryCentral Office.Customer Premises.Customer Premises Equipment. Terminal equipment supplied by either the custom

Pagina 32

IN-15100-A2-GB22-00 December 1996IndexAAnalog Interface, C-1CCentral Office, 1-1Configuration Menu, 3-3Download Firmware, 3-12Hardware Setup, 3-6

Pagina 33 - Pin Assignments

IndexIN-25100-A2-GB22-00December 1996RRADSL (Rate Adaptive Digital Subscriber Loop), 1-2RAM Requirements, 1-3Remote Loopback Testfailed, 3-11settin

Pagina 34 - Ethernet Interface

Important Regulatory Information B5100-A2-GB22-00 December 1996Important Safety Instructions1. Read and follow all warning notices and instructions ma

Pagina 35 - RS-232 Interface

Important Regulatory Information C5100-A2-GB22-00December 1996Declaration of ConformityThis Declaration of Conformity is made by Paradyne Corporation

Pagina 36 - Technical Specifications

i5100-A2-GB22-00December 1996ContentsAbout This Guide Purpose and Audience iv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 37 - Glossary

Contents ii5100-A2-GB22-00December 19963 Using the HotWire Diagnostics Utility Troubleshooting 3-1. . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 38

iii5100-A2-GB22-00December 1996About This GuidePurpose and AudienceThis guide describes how to install and run diagnostics on the 5170 RemoteTerminat

Pagina 39

About This Guide iv5100-A2-GB22-00December 1996Product-Related DocumentsDocument Number Document Title5100-A2-GB20HotWire 5100 DSL Access System Centr

Commenti su questo manuale

Nessun commento

Sony CDX-M1000TF manuals

Owner’s manuals and user’s guides for Alarm clocks Sony CDX-M1000TF.
We providing 1 pdf manuals Sony CDX-M1000TF for download free by document types: Operations Instructions


Sony CDX-M1000TF Operations Instructions (84 pages)


Brand: Sony | Category: Alarm clocks | Size: 2.86 MB |

  

Table of contents

CDX-M1000TF

1

Welcome !

2

Table of Contents

3

Location of controls

4

Precautions

6

Notes on discs

6

About MP3 files

7

IROORZV

8

General top menu display

9

Getting Started

10

CD Player

11

CD/MD Unit (optional)

11

Display items

12

Playing tracks repeatedly

13

Playing tracks in random

13

Labelling a CD

14

Storing stations

15

Locating a disc by name

15

Receiving the stored stations

16

Storing only desired stations

17

Overview of RDS

18

Automatic retuning for best

19

Receiving traffic

20

Presetting RDS stations with

20

AF and TA setting

20

Tuning in stations by

21

Setting the clock

22

Image Settings

23

SCREEN IMAGE

24

Clearing display characters

25

Changing the translucence

25

Setting a Plaque

26

Setting the character colour

26

Selecting the display period

27

Other Functions

28

Adjusting the sound

29

Quickly attenuating the

29

Changing the sound and

30

Setting the Dynamic

31

Soundstage Organiser (DSO)

31

Setting the equaliser (EQ7)

31

Adjusting the front and rear

32

Adjusting the volume of the

33

Connecting auxiliary audio

34

Setting the security code

35

Additional Information

36

Removing the unit

37

Specifications

38

Troubleshooting

39

Error displays/Message

40

About ID3 tag version 2

41

 配以選購件 CD/MD 裝置時可使用的功能

43

為保持高品質聲音

46

有關 LCD 顯示幕注意事項

46

關於 MP3 檔案

47

MP3 檔案的播放順序

48

普通頂部選單顯示

49

CD/MD 裝置 (選購件)

51

當更改光碟 / 樂曲集 *

52

/ 樂曲時,新光碟 /

52

樂曲集 / 樂曲中任何預先錄製的標題將自動

52

顯示。 如果 “AutoScroll"設定為 “ON",

52

名稱將捲動顯示 (第 30 頁)。

52

以隨機順序播放樂曲

53

通過名稱找出光碟

55

收聽已儲存的電台

56

僅儲存所要的電台

57

通過列表調入電台

57

頻譜分析器 / 全景 / 螢幕節能模式:

58

用於最佳接收效果的自動

59

用 AF 和 TA 設定預設 RDS

60

通過節目類型調入電台

61

 即使正在收聽 RDS 電台,CT 功能也可能不起作用。

62

 用 CT 功能設定的時間可能與實際時間有差異。

62

選擇顯示模式和顯示圖案

63

自動消除顯示字元

65

改變字元的透明率

65

如果 “Plaque"設定為 “ON",您所調節的

66

“BlendLevel"設定無效。

66

選擇影像的顯示時間

67

使用旋轉式控制器

68

改變聲音和顯示設定

70

設定動態攝影棚管理器

71

設定均衡器 (EQ7)

71

調節前後揚聲器音量

72

調節超重低音揚聲器音量

73

連接輔助音頻裝置

74

顯示 Code Del

75

鋰電池的註意事項

76

正確定位開鎖鑰匙。

77

CD 播放機部分

78

出錯顯示 / 訊息

80

關於 ID3 標籤版本 2

81

Sony Corporation

84





More products and manuals for Alarm clocks Sony

Models Document Type
ICF-C218 Operations Instructions      Sony ICF-C218 User manual, 2 pages
CFD-E77L Operations Instructions    Sony CFD-E77L User manual, 64 pages
ICF-CD3iP Operations Instructions   Sony ICF-CD3iP User manual [en] , 2 pages
ICF-CD831 Operations Instructions   Sony ICF-CD831 User manual, 2 pages
ICF-C255RC User Manual      Sony ICF-C255RC User manual, 2 pages
ICF-CD7000 User Manual    Sony ICF-CD7000 Instruções de operação, 2 pages
ICF-C773L User Manual     Sony ICF-C773 Instruções de operação, 2 pages
ICF-C263 User Manual   Sony ICF-C263 User manual, 2 pages
ICF-C717PJ User Manual    Sony ICF-C717PJ Bedienungsanleitung, 2 pages
ICF-C115L User Manual    Sony ICF-C115 Instruções de operação, 2 pages
ICF-C318 User Manual      Sony ICF-C318 Owner's manual, 2 pages
XDR-DS21BT User Manual   Sony XDR-DS21BT User manual, 2 pages
ICF-CL75IP User Manual    Sony ICF-CL70 Istruzioni per l'uso, 68 pages
ICF-CD853 User Manual      Sony ICF-CD853 User manual, 2 pages
ICF-C233 User Manual       Sony ICF-C233 User manual, 2 pages
ICF-C795RC User Manual      Sony ICF-C795RC User manual, 2 pages
ICF-C717PJ User Manual    Sony ICF-C717PJ User manual, 2 pages
ICF-C273L User Manual      Sony ICF-C273 Istruzioni per l'uso, 2 pages
ICF-C113 User Manual      Sony ICF-C113L User manual, 2 pages
ICF-C113 User Manual     Sony ICF-C113L User manual, 2 pages